Customer: Bau- und Liegenschaftsbetrieb NRW, Aachen
User: Lehrstuhl für VerbrennungsKraftmaschinen (VKA), RWTH Aachen
General planner: Lepel plus Generalplanungsgesellschaft mbH, Cologne
Architect: LEPEL & LEPEL, Architektur, Innenarchitektur, Cologne
Net costs, building services €: 16,700,000.00
Project period: 2007 until 2014
Services: Planning and monitoring, sanitary systems, high pressure mist system in the test benches, heating systems, air conditioning, refrigeration, cooling ceilings, electrical engineering, communications engineering, information technology, materials handling, building management systems, measurement and control technology, building automation, external drainage, underground pipes, fire extinguishing systems, thermal simulation, flow simulation, laboratory equipment, fire protection
Award: Auszeichnung guter Bauten 2014, BDA Aachen
From 2007 to 2012, a new competence center for research and development in the area of engine technologies was built for the Institute for Combustion Engines (VKA) at RWTH Aachen University: the Center for Mobile Propulsion (CMP). The CMP's building complex, which comprises three different structures, was designed by the Cologne-based architecture firm Lepel & Lepel. A test-center building has been designed as a closed, cubic structure with an external facade of black exposed concrete. To the south, it is abutted by a light-flooded, glass-walled administrative tract, with a Z-shaped floor plan and softly rounded edges, that houses offices, classrooms and laboratory areas. A plant building is situated to the west of the test-center structure, and the two buildings are connected via an enclosed bridge at the upper floor level. The heat produced by combustion engines running in the test center and by the chillers for its cold water supply systems is recovered and fed into the complex's static and dynamic heating circuits. The static heating surfaces and dynamic air heaters that are fed by the waste-heat recovery system are optimized for relatively low system temperatures, since the waste heat as recovered has temperatures in the 40°C - 60°C range. The complex is also equipped with underfloor heating systems, near-surface concrete-core activation, heating and cooling ceilings and ventilation systems that operate with relatively low supply-air temperatures. Virtually all of the test-center structure, and all the complex's offices, classrooms and laboratory areas, are air-conditioned and force-ventilated. For standardized testing processes, the temperatures and humidity levels required in the combustion-air supply for the test beds, and in the air supply for the laboratories, can be preset and controlled throughout a defined set point range. To minimize heating / cooling energy requirements, all major ventilation systems for process air and hygienically required air exchange are also equipped with highly efficient heat recovery systems. When outdoor temperatures are low, cooling requirements for structures and processes are met with free cooling, via adjustable-performance recooling systems. As outdoor temperatures and/or cooling requirements increase, cooling capacity is added via district cooling systems and electrical water chillers.
Images 1-7: © Jens KirchnerImages 11-18: © Solveig Böhl (ZWP Ingenieur-AG)
Technical facts:
Award:BDA AachenAuszeichnung guter Bauten 2014
Further projects for RWTH Aachen:Auditorium RWTH AachenInstitut für Physikalische Chemie
Further projects with LEPEL & LEPEL, Architektur, Innenarchitektur, Cologne:Ernst Flatow Haus, CologneKinderklinik, CologneFachhochschule Wismar
More:LEPEL & LEPEL
Read more:> Dynamic simulation> Flow simultion
We use cookies that are required for the basic functionality of this website. You decide on each further use yourself.
Cookies that are not absolutely necessary may be cause transmission personal data. For further information, please refer to our Privacy Policy and Imprint.
With your selection you determine the integration of external services and the associated data storage:
Forwarding of data outside the EU
Due to your decision, data about your user behavior may also be transferred to companies outside the European Union and may therefore be subject to the risk of access by national security authorities, without you being able to benefit from protection of your rights in line with European standards.